- 진공에서 최대 280 MPa - 0.008% or 0.01% of reading 불확도 - 최대 2개 압력센서 내장 - 자동 압력범위 생성   Premium performance in a compact and rugged instrument Independent quartz reference pressure transducer modules (Q-RPTs) with individual self-defense systems (SDS™) (See Q-RPT module advantages under "Features.") Infinite Ranging and AutoRange™ Differential measurement mode […]

상세 보기

- 진공에서 최대 280 MPa
- 0.008% or 0.01% of reading 불확도
- 최대 2개 압력센서 내장
- 자동 압력범위 생성

 

Premium performance in a compact and rugged instrument

  • Independent quartz reference pressure transducer modules (Q-RPTs) with individual self-defense systems (SDS™) (See Q-RPT module advantages under "Features.")
  • Infinite Ranging and AutoRange™
  • Differential measurement mode (channel 1- channel 2)
  • 15 kPa (2.2 psi) compound gauge Q-RPT with turndown to < 3 kPa (0.4 psi)
  • Integrates with PPC4 as external reference measurement device
  • Battery/charger pack available
  • RPM4 carries on the RPM line's tradition of combining very high end performance with ruggedness and reliability
  • Stability based Ready/Not Ready indication
  • Built-in fluid head corrections
  • User defined pressure units
  • Intelligent AutoZero™ function
  • Remote [ENTER] switch
  • Large character, easy to read display
  • 12VDC power and battery pack option
  • External valve drivers
  • RS232 and IEEE-488 communications
  • PC based recalibration utility software included
  • Free LabVIEW® drivers
  • Flash memory for simple and free embedded

 

Description
RPM4 is much more than a traditional pressure indicator. State of the art performance from very low pressure to 280 MPa (40,000 psi)… advanced on-board features… compact and rugged… full local and remote communications… RPM4 is the perfect solution in a wide variety of high end pressure calibration, testing and measurement applications.Infinite Ranging™ and AutoRange™

Infinite Ranging gives RPM4 unprecedented versatility in adapting to the specific range of operation. With the easy-to-use AutoRange function, a few simple key strokes or a single remote command string at the start of a test adapt every feature of the pressure monitor to optimize it for the range to be covered. Just enter the maximum pressure and the measurement mode. AutoRange then:

  • Selects and activates the most appropriate Q-RPT to cover the specified range and measurement mode.
  • Sets the pressure unit of measure. - Activates absolute, gauge or compound gauge measurement.
  • Adjusts display resolution to the appropriate level for the range.
  • Adjusts overpressure alarms to the actual range of operation.
  • Reduces measurement uncertainty proportionally to the selected range (premium class Q-RPTs only).

Note: The use of RPM4’s Infinite Ranging and AutoRange feature is recommended to optimize operation for a specific range but is not required to obtain "% of reading measurement specifications.

SDS™ Q-RPT self defense system

All Q-RPT modules up to 7 MPa (1 000 psi) include the unique Self Defense System™ (SDS). SDS valves automatically isolate and vent the module's Q-RPT when it is not in use or an overpressure is about to occur. With SDS, any Q-RPT module can be left connected to pressure up to 10 MPa (1 500 psi) without needing to isolate or disconnect it.

Advanced on-board functions

RPM4 provides a variety of advanced on-board pressure data functions including:

  • Special data such as pressure average over time, rate of change, hi/lo, freeze, deviation from set point.
  • Differential mode directly measures the difference between two Q-RPTs including taring at the line pressure.
  • Parallel measurement uses two Q-RPTs redundantly as one.
  • Leak check measures average pressure rate of change over a user set time period.
  • AutoTest automates calibration routines with tolerance testing and data logging.

Quartz reference pressure transducer (Q-RPT) modules

RPM4's outstanding pressure measurement specifications are made possible by Fluke Calibration’s exclusive quartz reference pressure transducer (Q-RPT) modules.

Q-RPTs measure pressure by measuring the change in the natural oscillating frequency of a quartz crystal with pressure induced stress. To be qualified for use in a Q-RPT module, each transducer is individually evaluated and characterized using primary pressure standards. Only transducers exhibiting required levels of linearity, repeatability and stability are selected. A proprietary compensation model, derived from more than 15 years experience with thousands of quartz pressure transducers, is applied to optimize the metrological characteristics needed in a transfer standard. Standard and premium class Q-RPT modules are available to best fit your performance and budgetary requirements.

A unique dynamic compensation for atmospheric pressure system uses an independent on-board barometer to provide seamless switching between absolute, gauge and compound gauge modes at any time. The barometer is used only to measure the small variations in atmospheric pressure that occur during gauge mode operation so its absolute error and drift over time do not contribute to measurement uncertainty. Q-RPT modules offer the advantages of:

  • % of reading measurement uncertainty with AutoRange span turndown available
  • Negligible warm up time
  • No gas species dependence
  • Quartz element isolated from test medium
  • Low sensitivity to orientation

Q-PRTs and ranges

Q-RPT
Designation

SI Version

US Version

Measurement MODE(s)
Supported

Operating
Media

SDSTM
Self
Defense
System

  Maximum Range [kPa] Absolute

 Maximum Range [kPa] Gauge

 Maximum Range [psi] Absolute

  Maximum Range [psi] Gauge

A280M-L

280 000

280 000

40 000

40 000

Absolute, Gauge and Compound Gauge

Gas Stndard
Oil available

Not
available

A200M-L

200 000

200 000

30 000

30 000

A140M-L

140 000

140 000

20 000

20 000

A100M-L

100 000

100 000

15 000

15 000

A70M

70 000

70 000

10 000

10 000

Gas Standard
Oil available
Gas only

A40M

40 000

40 000

6 000

6 000

A20M

20 000

20 000

3 000

3 000

A14M

14 000

14 000

2 000

2 000

A10M

10 000

10 000

1 500

1 500

Included

A7M

7 000

7 000

1 000

1 000

A3.5M

3 500

3 500

500

500

Gas only

A2M

2 000

2 000

300

300

A1.4M

1 400

1 400

200

200

A700K

700

700

100

100

A350K

350

250

50

35

A200K

200

100

30

15

A160K

160

60

23

8

A100K

110

10

16

1.5

BA100K1

110

-

16

-

G200K

-

200

-

30

Gauge only

G100K

-

100

-

15

BG15K2

-

15

-

2.2

G15K

-

15

-

2.2

1 BA100K is a barometer with a low point of 70 kPa (10 psia).
2 BG15K is bidirectional gauge from - 15 to + 15 kPa (- 2.2 to + 2.2 psi).

Compatible with PPC4 Automated Pressure Controller

RPM4 can be used as an external reference pressure measurement device for a Fluke Calibration PPC4, fully automated, pressure controller/calibrator. One or two RPM4s can be "daisy chained" to PPC4 by 9-pin RS232 cable(s). The RPM4's Q-RPTs become part of the PPC4 system and are managed by PPC4 transparently to the user. There is only one test connection for the PPC4 system's full range of operation.

 

Specifications
General
Power Requirements 85 to 264 VAC, 50/60 Hz,
25 VA max and 12 VDC @ 9 Ahr
Battery/Charger: 100 to 240 VAC, 50/60 Hz
Normal Operating Temperature Range 15 to 35 °C
Vibration Meets MIL-T-28800D
Weight (Typical) 5 kg (11 lb)
Dimensions 10 cm H x 22.7 cm W x 24 cm D (3.9 in. x 8.9 in. x 9.5 in.)
Battery/Charger: 8 cm H x 22.5 cm W x 20 cm D (3.1 in. x 8.9 in. x 7.9 in.)
Communications Ports RS232 (COM1, COM2), IEEE-488.2
Operating Modes Absolute, gauge, compound gauge, differential
Pressure Ranges Vacuum to 280 MPa (40,000 psi)
Operating Media Q-RPTs lower than A7M Gas only
All others Either gas or oil
Calibration A2LA accredited calibration report included
Pressure Connections Up to A70M: 1/8 in. NPT F
Above A70M: DH500 (equivalent to AE250C)
CE Mark Available, must be specified
Measured pressure (Q-RPT)
Warm Up Time 30 minute temperature stabilization recommended from cold power up
Resolution To 1 ppm, user adjustable
Predicted One Year Stability1 ± 0.005 % of reading all ranges and classes
Precision2 Q-RPTs up to A10M (1,500 psi)
Standard Class: ± 0.008 % of reading ± 0.005 % of reading, or 0.0024% of Q-RPT span, whichever is greater4
Premium Class: ± 0.005 % of reading ± 0.005 % of reading, 0.0015% of AutoRanged span or 0.0005% of Q-RPT span, whichever is greater5
Measurement Uncertainty3 Q-RPTs up to A10M (1,500 psi)
Standard Class: ± 0.010 % of reading or 0.0030% of Q-RPT span, whichever is greater4
Premium Class: ± 0.008 % of reading, 0.0024% of AutoRanged span, or 0.0007% of Q-RPT span, whichever is greater
Precision2 Q-RPTs A14M TO A140M (2,000 to 20,000 psi)
± 0.012 % of reading or 0.0036% of Q-RPT span, whichever is greater4
Measurement Uncertainty3 Q-RPTs A14M TO A140M (2,000 to 20,000 psi)
± 0.013 % of reading or 0.0039% of Q-RPT span, whichever is greater
Precision2 QRPT’s A200MN to A280M (30,000 to 40,000 psi)
± 0.015 % of reading or 0.0045% of Q-RPT span, whichever is greater
Measurement Uncertainty3 QRPT's A200MN to A280M (30,000 to 40,000 psi)
± 0.018 % of reading or 0.0054% of Q-RPT span, whichever is greater4

1. Predicted one year stability limit (k=2) assuming regular use of AutoZero function. Absolute mode predicted one year stability     without use of AutoZ is ± (0.005 % Q-RPT span + 0.005 % of reading). QRPT’s A200MN to A280M (30,000 to 40,000 psi).

2. Combined linearity, hysteresis and repeatability. Add ± 1 Pa (0.00015 psi) in gauge mode with an Axxx Q-RPT for the resolution     and short term stability of the on-board barometer.

3. Maximum deviation of the Q-RPT indication from the true value of applied pressure including precision, predicted one year stability,     temperature effect and calibration uncertainty, combined and expanded (k=2) following the ISO “Guide to the Expression of     Uncertainty in Measurement.

4. % of reading value times measured pressure from 100 to 30 % of Q-RPT span. Under 30 % of Q-RPT span, % of reading value times    30 % of Q-RPT span. For example, if the QRPT is a Standard A160K, the Measurement Uncertainty in pressure is 0.010% times the    measured pressure to 48 kPa (160 kPa span x 30%) and 0.0048 kPa (160 kPa span x 30% x 0.01%) under 48 kPa.

5. % of reading value times measured pressure from 100 to 30 % of AutoRanged span. Under 30% of AutoRanged span, % of reading    value times 30% of AutoRanged span. If AutoRanged span is less then 30% of maximum Q-RPT span, % of reading values times    measured pressure, or % of reading times 9% of Q-RPT span, whichever is greater. For example, if the Q-RPT is a Premium A160K    and AutoRanged span is 160 kPa, the Measurement Uncertainty in pressure is measured pressure x 0.008% to 48 kPa (160 kPa    AutoRanged span x 30%) and 0.0038 kPa (160 kPa span x 30% x 0.008%) under 48 kPa. If the AutoRanged span is 100 kPa (greater    than 30% of 160 kPa maximum Q-RPT span), the Measurement Uncertainty in pressure is measured pressure x 0.008% to 30 kPa    (100 kPa AutoRanged span x 30%) and 0.0025 kPa (100 kPa span x 30% x 0.008%) under 30 kPa. If the AutoRanged span is 30 kPa    (less than 30% of the 160 kPa maximum Q-RPT span), the Measurement Uncertainty in pressure is measured pressure x 0.008% to    14.4 kPa (160 kPa maximum Q-RPT span x 9%) and 0.0012 kPa (160 kPa maximum Q-RPT span x 9% x 0.008%) under 14.4 kPa.

 

 

Models and Accessories
Model Name Description
RPM4 mhhhac/mlllac Reference Pressure Monitor

Where:
mhhhac indicates the Hi Q-RPT designation.
c indicates Q-RT class (s for Standard, p for Premium)

mlllac indicates the Lo Q-RPT designation and class. Leave blank if there is no Lo Q-RPT.

See Q-RPT and ranges table under Features for available Q-RPTs.

RPM4 04 -1 US units version, -2 SI units version
RPM4 05 CE mark
RPM4 06 Special calibration
RPM4 07 Special test fluid, Hi Q-RPT (specify fluid)
RPM4 08 Special test fluid, Lo Q-RPT (specify fluid)
RPM4 09 -1 Special configuration, air data (A160K/A160K, A350K/A160K only)
Accessory Description Description
Battery Pack/Charger 12 V dc battery with charger
Rack Mount Kit Rack mount kit for standard 19 in. rack
Foot Switch Remote [ENTER] foot switch (part #3070940)
MPC1-3000 Manually operated gas pressure controller, pressure range vacuum to 20 MPa (3,000 psi)
MPC1-1000 Manually operated gas pressure controller, pressure range vacuum to 7 MPa (1,000 psi)
OPG1-30000 Hydraulic pressure generator - Includes: 1 qt. Di-2 Ethyl Hexyl Sebacate (synthetic oil), External tubing/adaptors for connection to a PG7302 or RPM4, and Operation and maintenance manual.
PK-7000-PPC/MPC Interconnections Kit - connect PG7102 to PPC or MPC pressure controller, and device under test.
PPCH-G 08-SP Special fluid
GB-H-152 Gas Booster Package Gas booster package designed to provide a regulated high pressure gas output to PPCH-G
PPCH 08-SP Special fluid
PPC4 07 Special calibration
PPCH 06-01 Enclosure (for bench applications)
PPCH 05-01 CE mark
PPCH 04-02 SI units version
상호명 : (주)아이엠피티 | 주소 : 서울특별시 송파구 충민로 10(문정동 628) 가든파이브 툴관 3층 A-8호 | 사업자등록번호 : 220-81-22489 | Tel : 02.552.8582 | Fax : 02.553.0388 | E-mail : impt@impt.co.kr | 고객정보 수집동의 약관
COPYLIGHTⓒ 2021. IMPT CO.,LTD. ALL RIGHTS RESERVED.
Design by 위디지털

데모 및
견적문의